Fiber Optic Coupled Ammeter (P02-0802)

$7,320.00
TESCO’s Fiber Optic Coupled Ammeter is a high-voltage, True RMS ammeter designed for safe, accurate current measurement in the field. This two-piece instrument links a high-voltage line sensor to a receiver unit at ground potential using a rugged fiber optic cable, which also serves as a high-insulation barrier—tested to 100 kV per foot.
Description
Unlike traditional clamp-on devices, the sensor slips directly over the conductor, eliminating moving parts and minimizing installation complexity. The system delivers a digital readout and a high-fidelity analog output (0–2V AC), reproducing the waveform of the current signal to approximately the 50th harmonic. This enables utilities and field technicians to connect standard analysis tools—such as scopes, recorders, and waveform analyzers—at ground level without exposure to high voltage.
Designed with robust urethane housings and built for harsh outdoor environments, the P02-0802 supports high-precision monitoring with advanced signal integrity in even the most demanding utility conditions
Key Features
- Measures 1–2,000 True RMS Amps with ±0.75% ±1mV accuracy
- Operates in high voltage environments up to 150 kV
- Wide sensor opening: 3.86 in (9.84 cm)
- Analog output (0–2V AC) accurate to ~50th harmonic for waveform analysis
- Digital readout and analog output at ground potential
- Fiber optic cable provides 100 kV/foot isolation, 500 kV max
- No clamping required; sensor slips over conductor
- Hot stick compatible with universal chuck adapter
- Shock- and water-resistant molded urethane housing
- Output impedance: 50 ohms minimum
- Frequency response up to 3,000 Hz
- Powered by two 9V batteries (one per unit), minimum 4-hour runtime
- Operating temperature: -22°F to +140°F (-30°C to +60°C)
Specifications
Unit | Details |
---|---|
Current | 1-2,000 True RMS Amps |
Voltage Environment | Up to 150 kV |
Accuracy | ±0.75 ±1mV (1-2,000A) |
Phase | ±1 Degree (1-2,000A) |
Wide Sensor Opening Width | 3.86 in, 9.84 cm |
20 Ampere Measurement | Range: 1-19.99 A, 100 mV RMS per amp |
200 Ampere Measurement | Range: 20-199.9 A, 10 mV RMS per amp |
2,000 Ampere Measurement | Range: 200-2,000 A, 1 mV RMS per amp |
Output Impedance | 50 ohms (minimum) |
Frequency Response | 3000 Hz or to the 50th Harmonic |
Fiber Optic Cable Length | 40’, 12.19 m |
Isolation | 100 kV per foot, 500 kV max |
Wide Sensor Weight | 6.0 lbs, 2.73 kg |
Housing | Shock & water-resistant molded urethane |
Hot Stick Mounting | Universal chuck adapter (hot stick not included) |
Battery | Two 9V alkaline or lithium (one per unit) |
Battery Life | Minimum 4 hours of continuous use |
Operating Temperature | -22° to +140° F (-30° to +60° C) |
Low-Temperature Requirement | Lithium battery required for use below -4°F (-20°C) |